- Manuals
- Brands
- Taurus Manuals
- Solar panel
- TAU-540W-144M
- Installation manual
Hide thumbs
-
- Contents
- Table of Contents
- Bookmarks
Table of Contents
-
Renuncia de Responsabilidad
-
Precauciones de Seguridad
-
Identificación de Producto
-
Consideraciones Ambientales
-
Instrucciones de Montaje
-
Toma de Tierra
-
Bypass Diode
-
Mantenimiento y Cuidado
-
Información de Contacto
-
Safety Precautions
-
Unpacking and Storage
-
Product Identification
-
Environmental Considerations
-
Site Selection
-
Mounting Instructions
-
Module Wiring
-
Electrical Configuration
-
Maintenance and Care
-
Contact Information
Advertisem*nt
Available languages
- EN
Available languages
- ENGLISH, page 12
Quick Links
Download this manual
TAU-450W-144M
TAU-540W-144M
Manual instalación
Installation manual
Table ofContents
Advertisem*nt
Table of Contents
Related Manuals for Taurus TAU-540W-144M
-
Solar panel Taurus TAU-450W-144M Installation Manual
(25 pages)
-
Solar panel Taurus PFB-0450-TG Installation Manual
Full black (25 pages)
Summary of Contents for Taurus TAU-540W-144M
- Page 1 TAU-450W-144M TAU-540W-144M Manual instalación Installation manual...
- Page 4 Lado afilado Sharp point 1. Tornillo de acero inox. Stainless steel bolt M4 x 30 2. Tuerca de acero inox. Stainless steel nut M4 3. Arandela de acero inoxidable. Stainless steel spring washer M4 4. 6. Arandela plana de acero inox. Stainless steel flat washer M4 5.
- Page 5 Tabla 1. Tipo Nombre o Modelo No: TAU-540W- Type Name or TAU-420W- TAU-425W- TAU-430W- TAU-440W- TAU-445W- TAU-450W- 144M(M6) 144M(M6) 144M(M6) 144M(M6) 144M(M6) 144M(M6) 144M(M6) Model No. : Voltaje de potencia máximo (Vmp) 40.18 40.32 40.45 40.71 40.84 41,40 40,79 Maximum Power Voltage(Vmp) Corriente de potencia máxima (Imp)
-
Page 6: Renuncia De Responsabilidad
- La instalación, manipulación y uso de los de módulos o cadenas. módulos Taurus Renovables están fuera del control de la empresa. Taurus Renovables no - NO concentre artificialmente la luz solar en asume ninguna responsabilidad por pérdidas, estos módulos solares. -
Page 7: Identificación De Producto
CONDICIONES CLIMATICAS el borde del techo y el borde externo del panel solar. - Los módulos de la serie Taurus Renovables Solar Crystalline pueden instalarse en las - Coloque los módulos para minimizar las siguientes condiciones durante más de 25 posibilidades de sombra en cualquier momento años. -
Page 8: Instrucciones De Montaje
Figura 1 y apriete a un par de 16 Nm. - Los módulos solares Taurus Renovables han pasado la prueba de corrosión por niebla sa- - Fig. 2 lina de los módulos fotovoltaicos y se pueden... -
Page 9: Toma De Tierra
El conductor de puesta - Los módulos Taurus Renovables Solar se a tierra debe entonces hacer una conexión a suministran con cables de cobre trenzados tierra utilizando un electrodo de puesta a tierra con un área de sección transversal de 4 mm²... -
Page 10: Bypass Diode
90 ° C y resistencia a la luz solar con - Cuando se instalan en sistemas regidos por aislamiento designado como cable fotovoltaico. las normas IEC, los módulos Taurus Reno- vables Solar normalmente no necesitan estar - El radio de curvatura mínimo de los cables debe ser de 43 mm. -
Page 11: Mantenimiento Y Cuidado
- Póngase en contacto con el equipo de servicio - Inspeccione todos los cables para verificar que posventa de Taurus Renovables Solar en: las conexiones estén firmes; los cables están www.taurusrenovables.com protegidos de la luz solar directa y ubicados lejos de áreas de recolección de agua. -
Page 12: Safety Precautions
Class A installations at voltages DISCLAIMER OF LIABILITY below 1500Vdc. This maximum voltage should - The installation, handling and use of Taurus not be exceeded at any time and, as the volta- Renovables modules are beyond company ge of the module increases, above data sheet control. -
Page 13: Product Identification
- Do NOT place modules directly on top of each SITE SELECTION other. - Taurus Renovables Solar Modules can be mounted in landscape and portrait orientation - Fig. 1 however the impact of dirt shading the solar cells can be minimized by orienting the product in portrait. -
Page 14: Mounting Instructions
MOUNTING WITH CLAMPS frames of PV modules. The devices have to - Taurus Renovables Solar has tested its mo- be installed in accordance with the grounding dules with a number of clamps from different device manufacturer’s specified instructions. -
Page 15: Module Wiring
Whilst some solar modules, manufac- - Taurus Renovables Solar modules are provi- tured by Taurus Renovables Solar, are certified ded with stranded copper cables with a cross to operate up to 1500V dc always check the sectional area of 4mm²... -
Page 16: Maintenance And Care
- To reduce the risk of PID, we strongly suggest - Check that all string fuses in each non/earthed that modules feature Taurus Renovables So- pole are operating. lar’s Anti-PID technology, which can be applied to any Taurus Renovables product. Alternati-... -
Page 17: Contact Information
- If you suspect that your installation is not working properly, then contact your installer immediately. - Contact your installer - Contact Taurus Renovables Solar after sales service team at:www.taurusrenovables.com - WARNING: For any electrical maintenance, the PV system must first be shut down. Improper maintenance can cause lethal electric shock and/or burns. - Page 19 Podrá encontrar el más cercano accediendo al Pour savoir lequel est le plus proche, vous pou- siguiente enlace web: http://taurus-home.com/ vez accéder au lien suivant : http://taurus-home. com/ También puede solicitar información relacionada poniéndose en contacto con nosotros por el telé- Vous pouvez aussi nous contacter pour toute fono que aparece al final de este manual.
- Page 20 ενημερώσεις του στο http://taurus-home.com/ pondo-se em contacto connosco. Pode fazer o download deste manual de Русский instruções e suas atualizações em http://taurus- ГАРАНТИЯ И ТЕХНИЧЕСКАЯ ПОДДЕРЖКА home.com/ Этот продукт защищен юридической гарантией в соответствии с действующим законодательством. Чтобы обеспечить соблюдение ваших...
- Page 21 Най-близкия до Вас сервиз можете да откриете на следния линк: ي أ ة ع ج ا ر م ك ي ل ع http://taurus-home. com/ ر و ث ع ل ا ك . ن ك ي م ة ي م س...
- Page 22 11 Horse Barrack Lane, 54000, Gibraltar 00350 200 75397 / 00350 200 Gibraltar 41023 Sapfous 7-9, 10553, Athens +30 21 0373 7000 Greece BP 206, GN, Conakry (224) 622204545 Guinea Unit H,13/F., World Tech Centre, Hong kong (852) 2448 0116 / 9197 3519 Hong Kong Késmárk utca 11-13, 1158, Budapest +36 1 370 4519...
- Page 24 Avda. Barcelona, s/n 25790 Oliana Spain...